{"id":4297951346759,"title":"Hanna Instruments Direct Soil EC Tester (HI98331)","handle":"hanna-direct-soil-ec-tester-hi98331","description":"\u003cdl\u003e\n\u003cdd class=\"tab-container\" font-size:=\"\" helvetica=\"\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv class=\"std\"\u003e\n\u003cul class=\"atf-features\" helvetica=\"\"\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eWaterproof\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e4.5' stainless steel penetration electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAutomatic Temperature Compensation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eThe HI98331 features a stainless steel penetration electrode that provides the ability to take direct measurements in soil. When calibration is needed, simply submerge the electrode tip into calibration solution and and enter calibration mode for automatic 1 point calibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eElectrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges of particles in a medium are moved under the influence of a potential diff‹erence. EC is a measure of concentration, however, it is non-specific for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eElectrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eFeatures at-a-glance:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eOne-point calibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eAutomatic calibration to 1413 µS\/cm conductivity standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eSamples automatically compensated for temperature variations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e Uses a fixed 2 degree Celsius temperature correction coefficient\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eStainless steel penetration electrode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eAllows for direct measurement in soil\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdiv helvetica=\"\" font-size:=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #000000;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 4000 μS\/cm; 0.00 to 4.00 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e1 μS\/cm; 0.01 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±50 μS\/cm (0 to 2000 μS\/cm), ±300 μS\/cm (2000 to 4000 μS\/cm); ±0.05 mS\/cm (0.00 to 2.00 mS\/cm), ±0.30 mS\/cm (2.00 to 4.00 mS\/cm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.0 to 50.0°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEC\/TDS Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, one-point at 1.41 mS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, temperature coefficient (β) fixed 2% \/ °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\/Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eCR2032 Li-ion approximately 100 hours of continuous use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrode\/Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e114 mm (4.5 “) Stainless steel penetration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e50 x 196 x 21 mm (2.0 x 7.7 x 0.9“)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e74 g (2.4 oz.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eHI98331 is supplied with a stainless steel penetration probe, batteries, and instrument quality certificate.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cbr\u003e\n\u003cdl\u003e\n\u003cdd class=\"tab-container\" font-size:=\"\" helvetica=\"\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\u003c\/div\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e","published_at":"2019-10-23T17:44:22+08:00","created_at":"2019-10-23T17:54:25+08:00","vendor":"Hanna","type":"Meters \u0026 Buffer Solutions","tags":["new-arrivals","Type_Tester"],"price":48000,"price_min":48000,"price_max":48000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30952864448583,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hanna Instruments Direct Soil EC Tester (HI98331)","public_title":null,"options":["Default Title"],"price":48000,"weight":200,"compare_at_price":null,"inventory_quantity":3,"inventory_management":"shopify","inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1129\/3552\/products\/1.png?v=1571824465","\/\/cdn.shopify.com\/s\/files\/1\/1129\/3552\/products\/2.png?v=1571824465"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1129\/3552\/products\/1.png?v=1571824465","options":["Title"],"content":"\u003cdl\u003e\n\u003cdd class=\"tab-container\" font-size:=\"\" helvetica=\"\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv class=\"std\"\u003e\n\u003cul class=\"atf-features\" helvetica=\"\"\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eWaterproof\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003e4.5' stainless steel penetration electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eAutomatic Temperature Compensation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eThe HI98331 features a stainless steel penetration electrode that provides the ability to take direct measurements in soil. When calibration is needed, simply submerge the electrode tip into calibration solution and and enter calibration mode for automatic 1 point calibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eElectrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges of particles in a medium are moved under the influence of a potential diff‹erence. EC is a measure of concentration, however, it is non-specific for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eElectrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eFeatures at-a-glance:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eOne-point calibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eAutomatic calibration to 1413 µS\/cm conductivity standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eSamples automatically compensated for temperature variations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e Uses a fixed 2 degree Celsius temperature correction coefficient\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eStainless steel penetration electrode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan style=\"color: #000000;\"\u003eAllows for direct measurement in soil\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdiv helvetica=\"\" font-size:=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #000000;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 4000 μS\/cm; 0.00 to 4.00 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e1 μS\/cm; 0.01 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±50 μS\/cm (0 to 2000 μS\/cm), ±300 μS\/cm (2000 to 4000 μS\/cm); ±0.05 mS\/cm (0.00 to 2.00 mS\/cm), ±0.30 mS\/cm (2.00 to 4.00 mS\/cm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.0 to 50.0°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEC\/TDS Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, one-point at 1.41 mS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, temperature coefficient (β) fixed 2% \/ °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\/Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eCR2032 Li-ion approximately 100 hours of continuous use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrode\/Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e114 mm (4.5 “) Stainless steel penetration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e50 x 196 x 21 mm (2.0 x 7.7 x 0.9“)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e74 g (2.4 oz.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eHI98331 is supplied with a stainless steel penetration probe, batteries, and instrument quality certificate.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cbr\u003e\n\u003cdl\u003e\n\u003cdd class=\"tab-container\" font-size:=\"\" helvetica=\"\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\u003c\/div\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e"}

Hanna Instruments Direct Soil EC Tester (HI98331)

Product Description
  • Waterproof
  • 4.5' stainless steel penetration electrode
  • Automatic Temperature Compensation

The HI98331 features a stainless steel penetration electrode that provides the ability to take direct measurements in soil. When calibration is needed, simply submerge the electrode tip into calibration solution and and enter calibration mode for automatic 1 point calibration.

Electrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges of particles in a medium are moved under the influence of a potential diff‹erence. EC is a measure of concentration, however, it is non-specific for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-

Electrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.

 

Features at-a-glance:

One-point calibration

  • Automatic calibration to 1413 µS/cm conductivity standard

Automatic Temperature Compensation (ATC)

  • Samples automatically compensated for temperature variations

  • Uses a fixed 2 degree Celsius temperature correction coefficient

Stainless steel penetration electrode

  • Allows for direct measurement in soil

 

Specifications

Conductivity Range

0 to 4000 μS/cm; 0.00 to 4.00 mS/cm (dS/m)

Conductivity Resolution

1 μS/cm; 0.01 mS/cm (dS/m)

Conductivity Accuracy

±50 μS/cm (0 to 2000 μS/cm), ±300 μS/cm (2000 to 4000 μS/cm); ±0.05 mS/cm (0.00 to 2.00 mS/cm), ±0.30 mS/cm (2.00 to 4.00 mS/cm)

Temperature Range

0.0 to 50.0°C

Temperature Resolution

0.1°C

Temperature Accuracy

±1°C

EC/TDS Calibration

automatic, one-point at 1.41 mS/cm

Temperature Compensation

automatic, temperature coefficient (β) fixed 2% / °C

Battery Type/Life

CR2032 Li-ion approximately 100 hours of continuous use

Electrode/Probe

114 mm (4.5 “) Stainless steel penetration

Environment

0 to 50°C (32 to 122°F); RH max 95% non-condensing

Dimensions

50 x 196 x 21 mm (2.0 x 7.7 x 0.9“)

Weight

74 g (2.4 oz.)

Ordering Information

HI98331 is supplied with a stainless steel penetration probe, batteries, and instrument quality certificate.

 