Hydroponics Farming Course, perfect for beginner. 30th Mar (Sat) 2024 - REGISTER

{"id":1317065162853,"title":"AZ Instrument Carbon Dioxide(CO2) Monitor and Controller AZ7530","handle":"az-instrument-carbon-dioxide-monitor-and-controller","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eUK Plug Version\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as\u003cstrong\u003e\u003cspan\u003e CO2 meter \u003c\/span\u003e\u003c\/strong\u003eor\u003cstrong\u003e\u003cspan\u003e Carbon Dioxide detector\u003c\/span\u003e\u003c\/strong\u003e, widely used for indoor air quality and greenhouse CO2 measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor greenhouse - \u003c\/strong\u003ehighly accurate digital CO2 controller measures the carbon dioxide level in the grow room and automatically turns on\/off the CO2 generator to accurately keep the CO2 PPM at the desired level\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor home use - \u003c\/strong\u003emeasure the carbon dioxide level in closed space and automatically turns on\/off ventilation system to get good air quality\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate 2-Channel low drift NDIR CO2 measuring\u003c\/li\u003e\n\u003cli\u003eProgrammable CO2 zone value \u0026amp; CO2 center value to control output power on\/off\u003c\/li\u003e\n\u003cli\u003eExternal CO2 sensor to be used in closed space\u003c\/li\u003e\n\u003cli\u003eDisplay real-time CO2 value\u003c\/li\u003e\n\u003cli\u003eDisplay CO2 chart with variable time zoom levels\u003c\/li\u003e\n\u003cli\u003eMax. \/Min. recall function\u003c\/li\u003e\n\u003cli\u003eAudible alarm warns CO2 concentration\u003c\/li\u003e\n\u003cli\u003eTarget zone indicator\u003c\/li\u003e\n\u003cli\u003eBuilt-in Day\/Night auto detection to override CO2 control\u003c\/li\u003e\n\u003cli\u003eMonitoring \u0026amp; Controlling CO2 value in greenhouse, residential and commercial building\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" cellspacing=\"3\" cellpadding=\"3\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#666666\" align=\"center\"\u003e\u003cspan\u003e\u003cspan color=\"#FFFFFF\" style=\"color: #ffffff;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#666666\" align=\"center\"\u003e\u003cspan\u003e\u003cspan color=\"#FFFFFF\" style=\"color: #ffffff;\"\u003e\u003cb\u003e7530\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"24\" align=\"center\"\u003e\u003cspan\u003eCO2 Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd height=\"24\" align=\"center\"\u003e\u003cspan\u003e0~5000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eCO2 Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e1 ppm (0~1000 ppm);\u003cbr\u003e5 ppm (1000~2000 ppm) ;\u003cbr\u003e10 ppm (>2000 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eCO2 Accuracy (below 3000 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e±50 ppm or ±5% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eCO2 Accuracy (above 3000 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e±7% of reading\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eWarm-up Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e30 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"24\" bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eCO2 Response Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd height=\"24\" bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e<2 min for 63% of step change or\u003cbr\u003e<4.6min for 90% step change\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eLCD Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e104(L) * 47(W) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eMeter Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e158(L) * 106(W) * 50(H) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eSensor Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e124(L) * 33(W) * 26(H) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e0~50℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eOperating RH%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e5~95% RH (avoid condensation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e-20~60℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eStorage RH%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e5~95% RH (avoid condensation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eAC 100~240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003ePiggyback socket load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e5A@250VAC; 10A@120VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e~700g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eStandard Package\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eSensor Unit, Monitor \u0026amp; Controller Unit,\u003cbr\u003eManual, Screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2018-07-21T17:09:47+08:00","created_at":"2018-07-21T17:12:55+08:00","vendor":"AZ Instrument","type":"Equipment","tags":["CO2"],"price":99000,"price_min":99000,"price_max":99000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12200519630949,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AZ Instrument Carbon Dioxide(CO2) Monitor and Controller AZ7530","public_title":null,"options":["Default Title"],"price":99000,"weight":1500,"compare_at_price":null,"inventory_quantity":6,"inventory_management":"shopify","inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cityfarm.my\/cdn\/shop\/products\/151634719141479000_1.png?v=1579792875","\/\/cityfarm.my\/cdn\/shop\/products\/NzUzMA_-1516346487-rQ1F3.png?v=1579792875"],"featured_image":"\/\/cityfarm.my\/cdn\/shop\/products\/151634719141479000_1.png?v=1579792875","options":["Title"],"media":[{"alt":"AZ Instrument Carbon Dioxide Monitor and Controller AZ7530 - CityFarm","id":617456500807,"position":1,"preview_image":{"aspect_ratio":1.839,"height":768,"width":1412,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/151634719141479000_1.png?v=1579792875"},"aspect_ratio":1.839,"height":768,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/151634719141479000_1.png?v=1579792875","width":1412},{"alt":"AZ Instrument Carbon Dioxide Monitor and Controller AZ7530 - CityFarm","id":617463742535,"position":2,"preview_image":{"aspect_ratio":0.707,"height":1753,"width":1240,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/NzUzMA_-1516346487-rQ1F3.png?v=1579792875"},"aspect_ratio":0.707,"height":1753,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/NzUzMA_-1516346487-rQ1F3.png?v=1579792875","width":1240}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eUK Plug Version\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as\u003cstrong\u003e\u003cspan\u003e CO2 meter \u003c\/span\u003e\u003c\/strong\u003eor\u003cstrong\u003e\u003cspan\u003e Carbon Dioxide detector\u003c\/span\u003e\u003c\/strong\u003e, widely used for indoor air quality and greenhouse CO2 measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor greenhouse - \u003c\/strong\u003ehighly accurate digital CO2 controller measures the carbon dioxide level in the grow room and automatically turns on\/off the CO2 generator to accurately keep the CO2 PPM at the desired level\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor home use - \u003c\/strong\u003emeasure the carbon dioxide level in closed space and automatically turns on\/off ventilation system to get good air quality\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate 2-Channel low drift NDIR CO2 measuring\u003c\/li\u003e\n\u003cli\u003eProgrammable CO2 zone value \u0026amp; CO2 center value to control output power on\/off\u003c\/li\u003e\n\u003cli\u003eExternal CO2 sensor to be used in closed space\u003c\/li\u003e\n\u003cli\u003eDisplay real-time CO2 value\u003c\/li\u003e\n\u003cli\u003eDisplay CO2 chart with variable time zoom levels\u003c\/li\u003e\n\u003cli\u003eMax. \/Min. recall function\u003c\/li\u003e\n\u003cli\u003eAudible alarm warns CO2 concentration\u003c\/li\u003e\n\u003cli\u003eTarget zone indicator\u003c\/li\u003e\n\u003cli\u003eBuilt-in Day\/Night auto detection to override CO2 control\u003c\/li\u003e\n\u003cli\u003eMonitoring \u0026amp; Controlling CO2 value in greenhouse, residential and commercial building\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" cellspacing=\"3\" cellpadding=\"3\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#666666\" align=\"center\"\u003e\u003cspan\u003e\u003cspan color=\"#FFFFFF\" style=\"color: #ffffff;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#666666\" align=\"center\"\u003e\u003cspan\u003e\u003cspan color=\"#FFFFFF\" style=\"color: #ffffff;\"\u003e\u003cb\u003e7530\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"24\" align=\"center\"\u003e\u003cspan\u003eCO2 Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd height=\"24\" align=\"center\"\u003e\u003cspan\u003e0~5000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eCO2 Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e1 ppm (0~1000 ppm);\u003cbr\u003e5 ppm (1000~2000 ppm) ;\u003cbr\u003e10 ppm (>2000 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eCO2 Accuracy (below 3000 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e±50 ppm or ±5% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eCO2 Accuracy (above 3000 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e±7% of reading\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eWarm-up Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e30 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"24\" bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eCO2 Response Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd height=\"24\" bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e<2 min for 63% of step change or\u003cbr\u003e<4.6min for 90% step change\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eLCD Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e104(L) * 47(W) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eMeter Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e158(L) * 106(W) * 50(H) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eSensor Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e124(L) * 33(W) * 26(H) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e0~50℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eOperating RH%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e5~95% RH (avoid condensation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e-20~60℃\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eStorage RH%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e5~95% RH (avoid condensation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eAC 100~240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003ePiggyback socket load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003e5A@250VAC; 10A@120VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#CCCCCC\" align=\"center\"\u003e\u003cspan\u003e~700g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eStandard Package\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cspan\u003eSensor Unit, Monitor \u0026amp; Controller Unit,\u003cbr\u003eManual, Screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

AZ Instrument Carbon Dioxide(CO2) Monitor and Controller AZ7530

Product Description

 

  • UK Plug Version

Also known as CO2 meter or Carbon Dioxide detector, widely used for indoor air quality and greenhouse CO2 measurement.

Application:

For greenhouse - highly accurate digital CO2 controller measures the carbon dioxide level in the grow room and automatically turns on/off the CO2 generator to accurately keep the CO2 PPM at the desired level

For home use - measure the carbon dioxide level in closed space and automatically turns on/off ventilation system to get good air quality

 

Features:

  • Accurate 2-Channel low drift NDIR CO2 measuring
  • Programmable CO2 zone value & CO2 center value to control output power on/off
  • External CO2 sensor to be used in closed space
  • Display real-time CO2 value
  • Display CO2 chart with variable time zoom levels
  • Max. /Min. recall function
  • Audible alarm warns CO2 concentration
  • Target zone indicator
  • Built-in Day/Night auto detection to override CO2 control
  • Monitoring & Controlling CO2 value in greenhouse, residential and commercial building
Model 7530
CO2 Range 0~5000 ppm
CO2 Resolution 1 ppm (0~1000 ppm);
5 ppm (1000~2000 ppm) ;
10 ppm (>2000 ppm)
CO2 Accuracy (below 3000 ppm) ±50 ppm or ±5% of reading, whichever is greater
CO2 Accuracy (above 3000 ppm) ±7% of reading
Warm-up Time 30 Seconds
CO2 Response Time <2 min for 63% of step change or
<4.6min for 90% step change
LCD Size 104(L) * 47(W) mm
Meter Size 158(L) * 106(W) * 50(H) mm
Sensor Size 124(L) * 33(W) * 26(H) mm
Operating Temperature 0~50℃
Operating RH% 5~95% RH (avoid condensation)
Storage Temperature -20~60℃
Storage RH% 5~95% RH (avoid condensation)
Power Supply AC 100~240 VAC
Piggyback socket load 5A@250VAC; 10A@120VAC
Weight ~700g
Standard Package Sensor Unit, Monitor & Controller Unit,
Manual, Screws
RM990.00
Maximum quantity available reached.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question