{"id":7513222316223,"title":"Hanna Instruments DiST®2 Waterproof TDS Tester (0.00-10.00 ppt) HI98302","handle":"hanna-instruments-dist-2-waterproof-tds-tester-0-00-10-00-ppt-hi98302","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Hanna Instruments HI98302 DiST\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e2 is a high-range total dissolved solids tester than can measure up to 10.00 ppt (g\/L). The DiST\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e2 is a rugged and reliable pocket-sized tester for use in the lab or field. This modern looking meter is only 0.7\" thick and extremely ergonomic, fitting comfortably in your hand. This tester keeps things simple with a two-button operation; one for ON\/OFF, the other for calibration.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Multi-level LCD\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExposed Temperature Probe for Fast Response\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSimple Two-Button Operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe DiST\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e 2 features a large multi-level LCD which displays both TDS and temperature readings simultaneously. The TDS readings are displayed with a 0.01 ppt (g\/L) resolution and with an accuracy of ±2% full scale. The TDS range of the HI98302 is from 0.00 to 10.00 ppt (g\/L). An exposed temperature sensor allows for rapid automatic temperature compensated TDS measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eTDS readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eCalibration is performed by pressing the dedicated calibration button. Once in calibration mode, submerge the probe in 6.44 ppt calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eSetup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"section-header text-center\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv class=\"grid-x grid-padding-x grid-padding-y small-up-1 medium-up-2 large-up-3\"\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cimg alt=\"lcd-hi98302\" src=\"https:\/\/www.hannainst.com\/hubfs\/001-website\/images\/lcd-hi98302.jpg\" class=\"feature-image float-center\"\u003e\u003cspan class=\"feature-header h4\"\u003eMulti-Level LCD\u003c\/span\u003eThe large LCD displays TDS, temperature, calibration tag, battery level and instability indicator.\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cimg alt=\"sensors-hi98304\" src=\"https:\/\/www.hannainst.com\/hubfs\/001-website\/images\/sensors-hi98304.jpg\" class=\"feature-image float-center\"\u003e\u003cspan class=\"feature-header h4\"\u003eExposed Temperature Probe\u003c\/span\u003eAn exposed temperature probe allows for an extremely fast and stable TDS measurement.\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cimg alt=\"two-buttons-hi98304\" src=\"https:\/\/www.hannainst.com\/hubfs\/001-website\/images\/two-buttons-hi98304.jpg\" class=\"feature-image float-center\"\u003e\u003cspan class=\"feature-header h4\"\u003eTwo-Button Operation\u003c\/span\u003eOnly two buttons for meter operation. One for on\/off and one for calibration.\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003ch5\u003eSlim, Ergonomic Design\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eWith rounded edges and a case that is only 17 mm (0.7”) thick, the HI98302 is thin and fits comfortably in the hand or pocket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eLarge Multi-level LCD\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both TDS and temperature simultaneously.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eTwo-button Operation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eOne for ON\/OFF, the other for calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eExposed Temperature Sensor\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eExposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either\u003cspan\u003e \u003c\/span\u003e\u003csup\u003eo\u003c\/sup\u003eC or\u003cspan\u003e \u003c\/span\u003e\u003csup\u003eo\u003c\/sup\u003eF.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGraphite Sensor\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eReduces polarization effects and does not oxidize resulting in a reliable and accurate reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cell small-12 large-auto\" data-details=\"\"\u003e\n\u003cdiv class=\"grid-x grid-padding-x grid-padding-y\" data-detail-item=\"\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eAutomatic Calibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calibration at 1382 ppm (mg\/L) with a single push of a button.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStability Indicator\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eA clock tag stability indicator will disappear to alert the user when the reading is stable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAutomatic shut-off\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUser-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLow battery indicator that is displayed when less than 10% battery life is remaining.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBattery % Level at Startup\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAt start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Name\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at 6.44 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC\/TDS Temperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC to TDS Conversion Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\/32.0 to 122.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V Li-ion \/ approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 g (2.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98302 (DiST 2) is supplied with CR2032 battery, 6.44 ppt calibration solution sachet (4), storage\/protection sleeve, instruction manual and quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2023-07-08T20:40:26+08:00","created_at":"2023-07-08T20:38:38+08:00","vendor":"Hanna","type":"Meters \u0026 Buffer Solutions","tags":["Type_Tester"],"price":31800,"price_min":31800,"price_max":31800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42411681939647,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hanna Instruments DiST®2 Waterproof TDS Tester (0.00-10.00 ppt) HI98302","public_title":null,"options":["Default Title"],"price":31800,"weight":200,"compare_at_price":null,"inventory_quantity":1,"inventory_management":"shopify","inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-cover-on_1.png?v=1688820001","\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new_1.jpg?v=1688820001","\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-probe_1.jpg?v=1688820001","\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-battery_1.jpg?v=1688820001"],"featured_image":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-cover-on_1.png?v=1688820001","options":["Title"],"media":[{"alt":null,"id":27279267758271,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-cover-on_1.png?v=1688820001"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-cover-on_1.png?v=1688820001","width":1200},{"alt":null,"id":27279267659967,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new_1.jpg?v=1688820001"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new_1.jpg?v=1688820001","width":1200},{"alt":null,"id":27279267692735,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-probe_1.jpg?v=1688820001"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-probe_1.jpg?v=1688820001","width":1200},{"alt":null,"id":27279267725503,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-battery_1.jpg?v=1688820001"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/files\/hi98302-new-battery_1.jpg?v=1688820001","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Hanna Instruments HI98302 DiST\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e2 is a high-range total dissolved solids tester than can measure up to 10.00 ppt (g\/L). The DiST\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e2 is a rugged and reliable pocket-sized tester for use in the lab or field. This modern looking meter is only 0.7\" thick and extremely ergonomic, fitting comfortably in your hand. This tester keeps things simple with a two-button operation; one for ON\/OFF, the other for calibration.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLarge Multi-level LCD\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExposed Temperature Probe for Fast Response\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSimple Two-Button Operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe DiST\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e 2 features a large multi-level LCD which displays both TDS and temperature readings simultaneously. The TDS readings are displayed with a 0.01 ppt (g\/L) resolution and with an accuracy of ±2% full scale. The TDS range of the HI98302 is from 0.00 to 10.00 ppt (g\/L). An exposed temperature sensor allows for rapid automatic temperature compensated TDS measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eTDS readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eCalibration is performed by pressing the dedicated calibration button. Once in calibration mode, submerge the probe in 6.44 ppt calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eSetup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"section-header text-center\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv class=\"grid-x grid-padding-x grid-padding-y small-up-1 medium-up-2 large-up-3\"\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cimg alt=\"lcd-hi98302\" src=\"https:\/\/www.hannainst.com\/hubfs\/001-website\/images\/lcd-hi98302.jpg\" class=\"feature-image float-center\"\u003e\u003cspan class=\"feature-header h4\"\u003eMulti-Level LCD\u003c\/span\u003eThe large LCD displays TDS, temperature, calibration tag, battery level and instability indicator.\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cimg alt=\"sensors-hi98304\" src=\"https:\/\/www.hannainst.com\/hubfs\/001-website\/images\/sensors-hi98304.jpg\" class=\"feature-image float-center\"\u003e\u003cspan class=\"feature-header h4\"\u003eExposed Temperature Probe\u003c\/span\u003eAn exposed temperature probe allows for an extremely fast and stable TDS measurement.\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cimg alt=\"two-buttons-hi98304\" src=\"https:\/\/www.hannainst.com\/hubfs\/001-website\/images\/two-buttons-hi98304.jpg\" class=\"feature-image float-center\"\u003e\u003cspan class=\"feature-header h4\"\u003eTwo-Button Operation\u003c\/span\u003eOnly two buttons for meter operation. One for on\/off and one for calibration.\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"feature cell\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003ch5\u003eSlim, Ergonomic Design\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eWith rounded edges and a case that is only 17 mm (0.7”) thick, the HI98302 is thin and fits comfortably in the hand or pocket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eLarge Multi-level LCD\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both TDS and temperature simultaneously.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eTwo-button Operation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eOne for ON\/OFF, the other for calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eExposed Temperature Sensor\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eExposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either\u003cspan\u003e \u003c\/span\u003e\u003csup\u003eo\u003c\/sup\u003eC or\u003cspan\u003e \u003c\/span\u003e\u003csup\u003eo\u003c\/sup\u003eF.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eGraphite Sensor\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eReduces polarization effects and does not oxidize resulting in a reliable and accurate reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cell small-12 large-auto\" data-details=\"\"\u003e\n\u003cdiv class=\"grid-x grid-padding-x grid-padding-y\" data-detail-item=\"\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eAutomatic Calibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calibration at 1382 ppm (mg\/L) with a single push of a button.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStability Indicator\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eA clock tag stability indicator will disappear to alert the user when the reading is stable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAutomatic shut-off\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUser-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLow battery indicator that is displayed when less than 10% battery life is remaining.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBattery % Level at Startup\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAt start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Name\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at 6.44 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC\/TDS Temperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC to TDS Conversion Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\/32.0 to 122.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V Li-ion \/ approx. 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 g (2.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98302 (DiST 2) is supplied with CR2032 battery, 6.44 ppt calibration solution sachet (4), storage\/protection sleeve, instruction manual and quality certificate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

Hanna Instruments DiST®2 Waterproof TDS Tester (0.00-10.00 ppt) HI98302

Product Description

The Hanna Instruments HI98302 DiST® 2 is a high-range total dissolved solids tester than can measure up to 10.00 ppt (g/L). The DiST® 2 is a rugged and reliable pocket-sized tester for use in the lab or field. This modern looking meter is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand. This tester keeps things simple with a two-button operation; one for ON/OFF, the other for calibration.

  • Large Multi-level LCD
  • Exposed Temperature Probe for Fast Response
  • Simple Two-Button Operation

The DiST® 2 features a large multi-level LCD which displays both TDS and temperature readings simultaneously. The TDS readings are displayed with a 0.01 ppt (g/L) resolution and with an accuracy of ±2% full scale. The TDS range of the HI98302 is from 0.00 to 10.00 ppt (g/L). An exposed temperature sensor allows for rapid automatic temperature compensated TDS measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

TDS readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Calibration is performed by pressing the dedicated calibration button. Once in calibration mode, submerge the probe in 6.44 ppt calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.

Setup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.

 

Overview

lcd-hi98302Multi-Level LCDThe large LCD displays TDS, temperature, calibration tag, battery level and instability indicator.
sensors-hi98304Exposed Temperature ProbeAn exposed temperature probe allows for an extremely fast and stable TDS measurement.
two-buttons-hi98304Two-Button OperationOnly two buttons for meter operation. One for on/off and one for calibration.

Features and Benefits

Slim, Ergonomic Design
  • With rounded edges and a case that is only 17 mm (0.7”) thick, the HI98302 is thin and fits comfortably in the hand or pocket.
Large Multi-level LCD
  • The LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both TDS and temperature simultaneously.
Two-button Operation
  • One for ON/OFF, the other for calibration.
Exposed Temperature Sensor
  • Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either oC or oF.
Graphite Sensor
  • Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.

Automatic Calibration

  • Automatic calibration at 1382 ppm (mg/L) with a single push of a button.

Stability Indicator

  • A clock tag stability indicator will disappear to alert the user when the reading is stable.

Automatic shut-off

  • User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.

Low Battery Indicator

  • Low battery indicator that is displayed when less than 10% battery life is remaining.

Battery % Level at Startup

  • At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.
Specification Name Detail
SKU HI98302
TDS Range 0.00 to 10.00 g/L (ppt)
TDS Resolution 0.01 g/L (ppt)
TDS Calibration automatic, one-point at 6.44 ppt
EC/TDS Temperature Compensation automatic from 0 to 50°C (32 to 122°F)
EC to TDS Conversion Factor 0.5
Temperature Range 0.0 to 50.0°C/32.0 to 122.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C / ±1.0°F
Battery Type / Life CR2032 3V Li-ion / approx. 250 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH 100% max
Dimensions 160 x 40 x 17 mm (6.3 x 1.6 x 0.7’’)
Weight 75 g (2.6 oz.)
Ordering Information HI98302 (DiST 2) is supplied with CR2032 battery, 6.44 ppt calibration solution sachet (4), storage/protection sleeve, instruction manual and quality certificate.
Warranty 1 year