Hydroponics Farming Course, perfect for beginner. 30th Nov 2024 (Sat) - REGISTER NOW

{"id":4474836746311,"title":"Hanna Instruments Marine Salinity Tester HI98319","handle":"hanna-marine-salinity-tester-hi98319","description":"\u003cp\u003eHI98319 is a digital salinity tester designed specifically for saltwater aquariums and displays results in parts per thousand (ppt)\u003c\/p\u003e\n\u003cp\u003ePractical Salinity Units (PSU), or specify gravity (S.G.).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThis waterproof tester uses an amperometric conductivity probe to determine the salt content in the water.  This robust tester displays the readings along with temperature on a large LCD.\u003c\/p\u003e\n\u003cp\u003eThe rugged waterproof tester is only 0.7\" thick and extremely ergonomic, fitting comfortably in your hand. \u003c\/p\u003e\n\u003cp\u003eIt keeps things simple with a two-button operation, one for ON\/OFF, the other for calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable id=\"zebra\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.0 to 70.0 ppt (g\/L)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.0 to 70.0 PSU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e1.000 to 1.041 S.G.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0.0 to 50.0°C; 32.0 to 122.0°F\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.1 ppt (g\/L)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.1 PSU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0.001\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0.1°C; 0.1°F\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eAccuracy @ 25 \u003csup\u003eo\u003c\/sup\u003eC\/ 77 \u003csup\u003eo\u003c\/sup\u003eF\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN\"\u003e\u003cspan\u003e±1 ppt for 0.0 to 40.0 ppt; ±2 ppt for readings over 40.0 ppt\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN\"\u003e\u003cspan\u003e±1 PSU for 0.0 to 40.0 PSU ; ±2 PSU for readings over 40.0 PSU\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN\"\u003e\u003cspan\u003e±0.001 S.G.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan lang=\"EN\"\u003e±\u003c\/span\u003e\u003cspan lang=\"EN\"\u003e0.5°C; 1°F\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eMethod\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eppt - International Oceanographic Tables\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003ePSU - Standard Methods for the Examination of Water and Wastewater, 2510 B, Electrical Conductivity Method\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eS.G.- Standard Methods for the Examination of Water and Wastewater, 2510 C, Density Method\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eautomatic, one point at 35 ppt\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eTemperature Compensation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eautomatic from 5.0 to 50.0°C (41.0 to 122.0°F)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eBattery Type \/ Life\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan lang=\"EN-US\"\u003eCR2032 3V Li-ion \u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e (1) \/ approximately\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e 100 hours of continuous use\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eAutomatic Shut-Off\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e8 minutes, 60 minutes, or disabled\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eEnvironment\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e68 g (2.4 oz.) without battery\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eContents:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI98319 is supplied with protective cap\u003c\/li\u003e\n\u003cli\u003e35.00 ppt calibration solution sachet (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery (1), plastic storage case\u003c\/li\u003e\n\u003cli\u003einstrument quality certificate and instruction  manual.\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2020-02-08T12:34:35+08:00","created_at":"2020-02-08T15:01:35+08:00","vendor":"Hanna","type":"Meters \u0026 Buffer Solutions","tags":["Type_Tester"],"price":44800,"price_min":44800,"price_max":44800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31742687969351,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hanna Instruments Marine Salinity Tester HI98319","public_title":null,"options":["Default Title"],"price":44800,"weight":150,"compare_at_price":null,"inventory_quantity":1,"inventory_management":"shopify","inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-angle-ppt.jpg?v=1581607308","\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-electrode-closeup.jpg?v=1581607308","\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-in-case.jpg?v=1581607308","\/\/cityfarm.my\/cdn\/shop\/products\/Salinity_test_1.jpg?v=1581607308","\/\/cityfarm.my\/cdn\/shop\/products\/Salinity_test_2.jpg?v=1581607308","\/\/cityfarm.my\/cdn\/shop\/products\/Screen_Shot_2020-02-07_at_10.39.20_AM.png?v=1581607308"],"featured_image":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-angle-ppt.jpg?v=1581607308","options":["Title"],"media":[{"alt":"Hanna Instruments Marine Salinity Tester HI98319 - CityFarm","id":6305664237639,"position":1,"preview_image":{"aspect_ratio":1.0,"height":720,"width":720,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-angle-ppt.jpg?v=1581607308"},"aspect_ratio":1.0,"height":720,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-angle-ppt.jpg?v=1581607308","width":720},{"alt":"Hanna Instruments Marine Salinity Tester HI98319 - CityFarm","id":6305664368711,"position":2,"preview_image":{"aspect_ratio":1.0,"height":720,"width":720,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-electrode-closeup.jpg?v=1581607308"},"aspect_ratio":1.0,"height":720,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-electrode-closeup.jpg?v=1581607308","width":720},{"alt":"Hanna Instruments Marine Salinity Tester HI98319 - CityFarm","id":6305664335943,"position":3,"preview_image":{"aspect_ratio":1.0,"height":720,"width":720,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-in-case.jpg?v=1581607308"},"aspect_ratio":1.0,"height":720,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/hi98319-in-case.jpg?v=1581607308","width":720},{"alt":"Hanna Instruments Marine Salinity Tester HI98319 - CityFarm","id":6300853174343,"position":4,"preview_image":{"aspect_ratio":0.986,"height":696,"width":686,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/Salinity_test_1.jpg?v=1581607308"},"aspect_ratio":0.986,"height":696,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/Salinity_test_1.jpg?v=1581607308","width":686},{"alt":"Hanna Instruments Marine Salinity Tester HI98319 - CityFarm","id":6300853207111,"position":5,"preview_image":{"aspect_ratio":0.968,"height":660,"width":639,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/Salinity_test_2.jpg?v=1581607308"},"aspect_ratio":0.968,"height":660,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/Salinity_test_2.jpg?v=1581607308","width":639},{"alt":"Hanna Instruments Marine Salinity Tester HI98319 - CityFarm","id":6300853141575,"position":6,"preview_image":{"aspect_ratio":1.506,"height":724,"width":1090,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/Screen_Shot_2020-02-07_at_10.39.20_AM.png?v=1581607308"},"aspect_ratio":1.506,"height":724,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/Screen_Shot_2020-02-07_at_10.39.20_AM.png?v=1581607308","width":1090}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHI98319 is a digital salinity tester designed specifically for saltwater aquariums and displays results in parts per thousand (ppt)\u003c\/p\u003e\n\u003cp\u003ePractical Salinity Units (PSU), or specify gravity (S.G.).\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThis waterproof tester uses an amperometric conductivity probe to determine the salt content in the water.  This robust tester displays the readings along with temperature on a large LCD.\u003c\/p\u003e\n\u003cp\u003eThe rugged waterproof tester is only 0.7\" thick and extremely ergonomic, fitting comfortably in your hand. \u003c\/p\u003e\n\u003cp\u003eIt keeps things simple with a two-button operation, one for ON\/OFF, the other for calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable id=\"zebra\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.0 to 70.0 ppt (g\/L)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.0 to 70.0 PSU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e1.000 to 1.041 S.G.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0.0 to 50.0°C; 32.0 to 122.0°F\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.1 ppt (g\/L)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e0.1 PSU\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0.001\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0.1°C; 0.1°F\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eAccuracy @ 25 \u003csup\u003eo\u003c\/sup\u003eC\/ 77 \u003csup\u003eo\u003c\/sup\u003eF\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN\"\u003e\u003cspan\u003e±1 ppt for 0.0 to 40.0 ppt; ±2 ppt for readings over 40.0 ppt\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN\"\u003e\u003cspan\u003e±1 PSU for 0.0 to 40.0 PSU ; ±2 PSU for readings over 40.0 PSU\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN\"\u003e\u003cspan\u003e±0.001 S.G.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan lang=\"EN\"\u003e±\u003c\/span\u003e\u003cspan lang=\"EN\"\u003e0.5°C; 1°F\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eMethod\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eppt - International Oceanographic Tables\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003ePSU - Standard Methods for the Examination of Water and Wastewater, 2510 B, Electrical Conductivity Method\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eS.G.- Standard Methods for the Examination of Water and Wastewater, 2510 C, Density Method\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eautomatic, one point at 35 ppt\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eTemperature Compensation\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eautomatic from 5.0 to 50.0°C (41.0 to 122.0°F)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eBattery Type \/ Life\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan lang=\"EN-US\"\u003eCR2032 3V Li-ion \u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e (1) \/ approximately\u003c\/span\u003e\u003cspan lang=\"EN-US\"\u003e 100 hours of continuous use\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eAutomatic Shut-Off\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e8 minutes, 60 minutes, or disabled\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eEnvironment\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"212\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"620\"\u003e\n\u003cp\u003e\u003cspan lang=\"EN-US\"\u003e\u003cspan\u003e68 g (2.4 oz.) without battery\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eContents:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI98319 is supplied with protective cap\u003c\/li\u003e\n\u003cli\u003e35.00 ppt calibration solution sachet (4)\u003c\/li\u003e\n\u003cli\u003eCR2032 battery (1), plastic storage case\u003c\/li\u003e\n\u003cli\u003einstrument quality certificate and instruction  manual.\u003c\/li\u003e\n\u003c\/ul\u003e"}

Hanna Instruments Marine Salinity Tester HI98319

Product Description

HI98319 is a digital salinity tester designed specifically for saltwater aquariums and displays results in parts per thousand (ppt)

Practical Salinity Units (PSU), or specify gravity (S.G.).

This waterproof tester uses an amperometric conductivity probe to determine the salt content in the water.  This robust tester displays the readings along with temperature on a large LCD.

The rugged waterproof tester is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand. 

It keeps things simple with a two-button operation, one for ON/OFF, the other for calibration.

Specifications

 

Range

0.0 to 70.0 ppt (g/L)

0.0 to 70.0 PSU

1.000 to 1.041 S.G.

0.0 to 50.0°C; 32.0 to 122.0°F

Resolution

0.1 ppt (g/L)

0.1 PSU

0.001

0.1°C; 0.1°F

Accuracy @ 25 oC/ 77 oF

±1 ppt for 0.0 to 40.0 ppt; ±2 ppt for readings over 40.0 ppt

±1 PSU for 0.0 to 40.0 PSU ; ±2 PSU for readings over 40.0 PSU

±0.001 S.G.

±0.5°C; 1°F

Method

ppt - International Oceanographic Tables

PSU - Standard Methods for the Examination of Water and Wastewater, 2510 B, Electrical Conductivity Method

S.G.- Standard Methods for the Examination of Water and Wastewater, 2510 C, Density Method

Calibration

automatic, one point at 35 ppt

Temperature Compensation

automatic from 5.0 to 50.0°C (41.0 to 122.0°F)

Battery Type / Life

CR2032 3V Li-ion  (1) / approximately 100 hours of continuous use

Automatic Shut-Off

8 minutes, 60 minutes, or disabled

Environment

0 to 50°C (32 to 122°F); RH max 100%

Dimensions

160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)

Weight

68 g (2.4 oz.) without battery


Contents:

  • HI98319 is supplied with protective cap
  • 35.00 ppt calibration solution sachet (4)
  • CR2032 battery (1), plastic storage case
  • instrument quality certificate and instruction  manual.
RM448.00
Maximum quantity available reached.