{"id":4297951346759,"title":"Hanna Instruments GroLine Direct Soil EC Tester HI98331","handle":"hanna-direct-soil-ec-tester-hi98331","description":"\u003cp\u003ehThe HI98331 Soil Test™ is a pocket tester specifically designed to directly measure soil conductivity (EC) and temperature. With a compact size, single button operation, and automatic calibration, Soil Test is an excellent choice for taking direct conductivity measurements in soil.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo need for soil slurries with the steel penetration electrode.\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature sensor for automatic temperature compensation.\u003c\/li\u003e\n\u003cli\u003eGreat for environmental and agricultural testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eLightweight \u0026amp; Portable\u003c\/h4\u003e\n\u003cp\u003eMade to fit comfortably in your hand, this compact EC tester for soil has an easy-to-view LCD. The stainless steel electrode allows for direct penetration into soil and soil slurries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eMade for Any User\u003c\/h4\u003e\n\u003cp\u003eThe HI98331 makes testing easy for any user with single button operation and automatic calibration to 1413 µS\/cm conductivity standard. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eIntegrated Temperature Probe\u003c\/h4\u003e\n\u003cp\u003eUsing a fixed 2%\/C temperature correction coefficient, this EC tester has a built-in temperature sensor so that samples are automatically compensated for temperature variations.\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eMeasure the Bulk EC of Your Soil with a Soil Conductivity Test\u003c\/h4\u003e\n\u003cp\u003eBulk electrical conductivity of soil measures the total conductivity. Total conductivity includes the EC of the soil, air, and moisture in your sample. All these things carry charged ions that would read as EC. This reading is very useful; you can calculate your pore water conductivity and saturated extract conductivity from the result. You would need to know your water content to perform that calculation (how much water there is in your soil).\u003c\/p\u003e\n\u003ch5\u003eHow To Measure the Bulk EC with your Direct Soil EC Meter\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003ePick your testing location.\u003c\/li\u003e\n\u003cli\u003eRinse the testing probe with deionized water, and make sure it is dry.\u003c\/li\u003e\n\u003cli\u003eCheck the soil and ensure that the soil is moist.\u003c\/li\u003e\n\u003cli\u003eUse a ruler or auger to make a hole in the soil. This keeps the testing depth consistent.\u003c\/li\u003e\n\u003cli\u003eInsert your soil conductivity tester directly into the soil, and take your measurement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 4000 μS\/cm; 0.00 to 4.00 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e1 μS\/cm; 0.01 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±50 μS\/cm (0 to 2000 μS\/cm), ±300 μS\/cm (2000 to 4000 μS\/cm); ±0.05 mS\/cm (0.00 to 2.00 mS\/cm), ±0.30 mS\/cm (2.00 to 4.00 mS\/cm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.0 to 50.0°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEC\/TDS Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, one-point at 1.41 mS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, temperature coefficient (β) fixed 2% \/ °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\/Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eCR2032 Li-ion approximately 100 hours of continuous use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrode\/Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e114 mm (4.5 “) Stainless steel penetration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e50 x 196 x 21 mm (2.0 x 7.7 x 0.9“)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e74 g (2.4 oz.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eHI98331 is supplied with a stainless steel penetration probe, batteries, and instrument quality certificate.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cbr\u003e\n\u003cdl\u003e\n\u003cdd class=\"tab-container\" helvetica=\"\" font-size:=\"\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\u003c\/div\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e","published_at":"2019-10-23T17:44:22+08:00","created_at":"2019-10-23T17:54:25+08:00","vendor":"Hanna","type":"Meters \u0026 Buffer Solutions","tags":["Type_GroLine","Type_Tester"],"price":59500,"price_min":59500,"price_max":59500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":30952864448583,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hanna Instruments GroLine Direct Soil EC Tester HI98331","public_title":null,"options":["Default Title"],"price":59500,"weight":200,"compare_at_price":null,"inventory_quantity":1,"inventory_management":"shopify","inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-hi98331__66312.1566586254.1280.1280_1.jpg?v=1627730855","\/\/cityfarm.my\/cdn\/shop\/products\/direct-soil-ec-tester-hi98331_1.jpg?v=1627730855","\/\/cityfarm.my\/cdn\/shop\/products\/2.png?v=1627730855","\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-battery-hi98331__89302.1566586347.1280.1280_1.jpg?v=1627730855"],"featured_image":"\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-hi98331__66312.1566586254.1280.1280_1.jpg?v=1627730855","options":["Title"],"media":[{"alt":null,"id":21905461182655,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-hi98331__66312.1566586254.1280.1280_1.jpg?v=1627730855"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-hi98331__66312.1566586254.1280.1280_1.jpg?v=1627730855","width":1200},{"alt":null,"id":21905483071679,"position":2,"preview_image":{"aspect_ratio":1.0,"height":720,"width":720,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/direct-soil-ec-tester-hi98331_1.jpg?v=1627730855"},"aspect_ratio":1.0,"height":720,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/direct-soil-ec-tester-hi98331_1.jpg?v=1627730855","width":720},{"alt":"Hanna Instruments GroLine Direct Soil EC Tester (HI98331) - CityFarm","id":5446557270087,"position":3,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/2.png?v=1627730855"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/2.png?v=1627730855","width":800},{"alt":null,"id":21905461215423,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-battery-hi98331__89302.1566586347.1280.1280_1.jpg?v=1627730855"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/cityfarm.my\/cdn\/shop\/products\/ec-direct-soil-tester-groline-battery-hi98331__89302.1566586347.1280.1280_1.jpg?v=1627730855","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003ehThe HI98331 Soil Test™ is a pocket tester specifically designed to directly measure soil conductivity (EC) and temperature. With a compact size, single button operation, and automatic calibration, Soil Test is an excellent choice for taking direct conductivity measurements in soil.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo need for soil slurries with the steel penetration electrode.\u003c\/li\u003e\n\u003cli\u003eIntegrated temperature sensor for automatic temperature compensation.\u003c\/li\u003e\n\u003cli\u003eGreat for environmental and agricultural testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eLightweight \u0026amp; Portable\u003c\/h4\u003e\n\u003cp\u003eMade to fit comfortably in your hand, this compact EC tester for soil has an easy-to-view LCD. The stainless steel electrode allows for direct penetration into soil and soil slurries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eMade for Any User\u003c\/h4\u003e\n\u003cp\u003eThe HI98331 makes testing easy for any user with single button operation and automatic calibration to 1413 µS\/cm conductivity standard. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003eIntegrated Temperature Probe\u003c\/h4\u003e\n\u003cp\u003eUsing a fixed 2%\/C temperature correction coefficient, this EC tester has a built-in temperature sensor so that samples are automatically compensated for temperature variations.\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eMeasure the Bulk EC of Your Soil with a Soil Conductivity Test\u003c\/h4\u003e\n\u003cp\u003eBulk electrical conductivity of soil measures the total conductivity. Total conductivity includes the EC of the soil, air, and moisture in your sample. All these things carry charged ions that would read as EC. This reading is very useful; you can calculate your pore water conductivity and saturated extract conductivity from the result. You would need to know your water content to perform that calculation (how much water there is in your soil).\u003c\/p\u003e\n\u003ch5\u003eHow To Measure the Bulk EC with your Direct Soil EC Meter\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003ePick your testing location.\u003c\/li\u003e\n\u003cli\u003eRinse the testing probe with deionized water, and make sure it is dry.\u003c\/li\u003e\n\u003cli\u003eCheck the soil and ensure that the soil is moist.\u003c\/li\u003e\n\u003cli\u003eUse a ruler or auger to make a hole in the soil. This keeps the testing depth consistent.\u003c\/li\u003e\n\u003cli\u003eInsert your soil conductivity tester directly into the soil, and take your measurement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 4000 μS\/cm; 0.00 to 4.00 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e1 μS\/cm; 0.01 mS\/cm (dS\/m)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±50 μS\/cm (0 to 2000 μS\/cm), ±300 μS\/cm (2000 to 4000 μS\/cm); ±0.05 mS\/cm (0.00 to 2.00 mS\/cm), ±0.30 mS\/cm (2.00 to 4.00 mS\/cm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.0 to 50.0°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0.1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e±1°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEC\/TDS Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, one-point at 1.41 mS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eautomatic, temperature coefficient (β) fixed 2% \/ °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\/Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eCR2032 Li-ion approximately 100 hours of continuous use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrode\/Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e114 mm (4.5 “) Stainless steel penetration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e50 x 196 x 21 mm (2.0 x 7.7 x 0.9“)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003e74 g (2.4 oz.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"239\"\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\"\u003e\n\u003cp\u003eHI98331 is supplied with a stainless steel penetration probe, batteries, and instrument quality certificate.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cbr\u003e\n\u003cdl\u003e\n\u003cdd class=\"tab-container\" helvetica=\"\" font-size:=\"\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\u003c\/div\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e"}
Hanna Instruments GroLine Direct Soil EC Tester HI98331
Related Products
Germination Sponge (1 sheet = 117 Cubes)
RM5.90 RM8.00
Hydroponics A & B Liquid Fertilizer for Leafy Greens
From RM15.00
47mm Net Pots
From RM2.50 RM10.00
Lettuce Butterhead
RM3.90
Coriander
RM3.90
Hydroponics pH Down Acid 250ml
RM11.70
Mini Germination Box
RM6.50